"Requested_prod_id","Requested_GTIN(EAN/UPC)","Requested_Icecat_id","ErrorMessage","Supplier","Prod_id","Icecat_id","GTIN(EAN/UPC)","Category","CatId","ProductFamily","ProductSeries","Model","Updated","Quality","On_Market","Product_Views","HighPic","HighPic Resolution","LowPic","Pic500x500","ThumbPic","Folder_PDF","Folder_Manual_PDF","ProductTitle","ShortDesc","ShortSummaryDescription","LongSummaryDescription","LongDesc","ProductGallery","ProductGallery Resolution","ProductGallery ExpirationDate","360","EU Energy Label","EU Product Fiche","PDF","Video/mp4","Other Multimedia","ProductMultimediaObject ExpirationDate","ReasonsToBuy","Bullet Points","Spec 1","Spec 2","Spec 3","Spec 4","Spec 5","Spec 6","Spec 7","Spec 8","Spec 9","Spec 10","Spec 11","Spec 12","Spec 13","Spec 14","Spec 15","Spec 16","Spec 17","Spec 18","Spec 19","Spec 20","Spec 21","Spec 22","Spec 23","Spec 24","Spec 25","Spec 26","Spec 27","Spec 28","Spec 29","Spec 30","Spec 31","Spec 32","Spec 33","Spec 34","Spec 35","Spec 36","Spec 37","Spec 38","Spec 39","Spec 40" "","","36554102","","APC","BR1200G-FR?KIT","36554102","","Uninterruptible Power Supplies (UPSs)","817","","","Power Saving Back-UPS RS 1200 230V CEE 7/5","20221021101432","ICECAT","1","83242","https://images.icecat.biz/img/norm/high/6859277-4774.jpg","293x500","https://images.icecat.biz/img/norm/low/6859277-4774.jpg","https://images.icecat.biz/img/gallery_mediums/img_6859277_medium_1481537724_7913_14419.jpg","https://images.icecat.biz/thumbs/6859277.jpg","","","APC Power Saving Back-UPS RS 1200 230V CEE 7/5","720 Watts / 1200 VA, 230V / 230V ","APC Power Saving Back-UPS RS 1200 230V CEE 7/5, 1.2 kVA, 720 W, 50/60 Hz, 445 J, 45 dB, Sealed Lead Acid (VRLA)","APC Power Saving Back-UPS RS 1200 230V CEE 7/5. Output power capacity: 1.2 kVA, Output power: 720 W, Input frequency: 50/60 Hz. Battery technology: Sealed Lead Acid (VRLA), Battery recharge time: 8 h. Product colour: Black, Cable length: 1.83 m. Width: 112 mm, Depth: 380 mm, Height: 301 mm. Battery type: APCRBC124, Nominal output voltage: 230 V, Filtering description: UL 1449","The Back-UPS RS offers high performance protection for your business and office computer systems. It provides abundant battery backup power, allowing you to work through medium and extended length power outages. It also safeguards your equipment from damaging surges and spikes that travel along utility, phone and network lines. A distinguishing feature of the Back-UPS RS is automatic voltage regulation (AVR). AVR instantly adjusts both low and high voltages to safe levels, so you can work indefinitely during brownouts and overvoltage situations, saving the battery for power outages when you need it most. Award-winning shutdown software automatically powers down your computer system in the event of an extended power outage. Additional features like audible alarms, LED status indicators, user replaceable battery, push-button circuit breakers and plentiful outlets (including transformer-block spaced outlets) make the Back-UPS RS the perfect unit to protect your business' productivity from the constant threat of power problems and lost data. \r\n\r\nGreen mode: Patent-pending operating mode that bypasses unused electrical components in good power conditions to achieve very high operating efficiency without sacrificing any protection.\r\n\r\nAudible alarms: Provide notification of changing flywheel conditions\r\n\r\nBattery failure notification: Provides early-warning fault analysis on batteries enabling timely preventive maintenance\r\n\r\nPower-saving outlets: Automatically cuts power to idle equipment to conserve electricity.\r\n\r\nLCD display: Alpha-Numeric Display which displays system parameters and alarms.\r\n\r\nBattery-protected and surge-only outlets: Reserves power capacity and run time for connected equipment that require battery back-up while providing surge only protection for less critical equipment\r\n\r\nCold-start capable: Provides temporary battery power when the utility power is out.\r\n\r\nHot-swappable batteries: Ensures clean, uninterrupted power to protected equipment while batteries are being replaced\r\n\r\nAutomatic self-test: Periodic battery self-test ensures early detection of a battery that needs to be replaced.\r\n\r\nAdjustable voltage sensitivity: Provides the ability to adapt the UPS for optimal performance in specific power environments or generator applications.\r\n\r\nAudible alarms: Provides notification of changing utility power and UPS conditions.\r\n\r\nUser-replaceable batteries: Increases availability by allowing a trained user to perform upgrades and replacements of the batteries reducing Mean Time to Repair (MTTR)\r\n\r\nUSB connectivity: Provides management of the UPS via a USB port (not available on all models).\r\n\r\nTransformer-block spaced outlets: Protect equipment with input transformer blocks without blocking access to other receptacles.\r\n\r\nBoost and Trim Automatic Voltage Regulation (AVR): Gives higher application availability by correcting low and high voltage conditions without using the battery\r\n\r\nAutomatic Voltage Regulation (AVR): Gives higher application availability by correcting low and high voltage conditions without using the battery.\r\n\r\nIntelligent battery management: Maximizes battery performance, life, and reliability through intelligent, precision charging.\r\n\r\nBuilding Wiring Fault Indicator: This LED informs users of potentially dangerous wiring problems in the wall circuit.\r\n\r\nAdjustable voltage sensitivity: Provides the ability to adapt the Power Conditioner for optimal performance in specific power environments or generator applications.\r\n\r\nAutomatic Voltage Regulation (AVR): Automatically steps up low voltage and steps down high voltage to levels that are suitable for your equipment.\r\n\r\nBattery fault detection: Monitors room and individual battery temperature changes for early detection of thermal runaway, shorted cells, open circuit, and bad battery.\r\n\r\nBattery-protected and surge-only outlets: Reserves power capacity and run time for connected equipment that require battery back-up while providing surge only protection for less critical equipment.\r\n\r\nSafety-agency approved: Ensures the product has been tested and approved to work safely with the connected service provider equipment and within the specified environment. \r\n\r\nPower conditioning: Protects connected loads from surges, spikes, lightning, and other power disturbances. \r\n\r\nAudible alarms: Provides notification of changing utility power and UPS conditions. \r\n\r\nAutomatic restart of loads after UPS shutdown: Automatically starts up the connected equipment upon the return of utility power. \r\n\r\nAutomatic self-test: Periodic battery self-test ensures early detection of a battery that needs to be replaced.\r\n\r\nBattery replacement without tools: Allows quick, easy battery replacement. \r\n\r\nLED status indicators: Quickly understand unit and power status with visual indicators. \r\n\r\nCold-start capable: Provides temporary battery power when the utility power is out. \r\n\r\nHot-swappable batteries: Ensures clean, uninterrupted power to protected equipment while batteries are being replaced \r\n\r\nResettable circuit breakers: Enables a quick recovery from overload events. \r\n\r\nTransformer-block spaced outlets: Protect equipment with input transformer blocks without blocking access to other receptacles. \r\n\r\nUser-replaceable batteries: Increases availability by allowing a trained user to perform upgrades and replacements of the batteries reducing Mean Time to Repair (MTTR) \r\n\r\nAdjustable voltage sensitivity: Provides the ability to adapt the UPS for optimal performance in specific power environments or generator applications. \r\n\r\nAdjustable voltage-transfer points: Maximizes useful battery life by widening the input voltage window or tightening the output voltage regulation. \r\n\r\nIntelligent battery management: Micro-processor controlled battery charging and diagnostic testing ensures maximum battery life. ","https://images.icecat.biz/img/norm/high/6859277-4774.jpg|https://images.icecat.biz/img/gallery/16713_6859277_7302.jpg","293x500|228x500","|","","","","","","","","","","Features","Output power capacity: 1.2 kVA","Output power: 720 W","Input frequency: 50/60 Hz","Surge energy rating: 445 J","Noise level: 45 dB","Audible alarm(s): Yes","Ports & interfaces","USB 2.0 ports quantity: 1","Modem (RJ-11) ports: 1","Ethernet LAN (RJ-45) ports: 1","Battery","Battery technology: Sealed Lead Acid (VRLA)","Battery recharge time: 8 h","Replacement battery cartridge: 1","Design","Product colour: Black","Cable length: 1.83 m","Operational conditions","Operating temperature (T-T): 0 - 40 °C","Storage temperature (T-T): -15 - 45 °C","Operating relative humidity (H-H): 0 - 95%","Storage relative humidity (H-H): 0 - 95%","Operating altitude: 0 - 9000 m","Non-operating altitude: 0 - 15000 m","Weight & dimensions","Width: 112 mm","Depth: 380 mm","Height: 301 mm","Weight: 11.6 kg","Package weight: 13.2 kg","Other features","Battery type: APCRBC124","Nominal output voltage: 230 V","Filtering description: UL 1449","Nominal input voltage: 230 V","Networking features: 10/100/1000 Base-T","Relative humidity: 0 - 95%","Operating temperature (T-T): 32 - 104 °F","Package dimensions (WxDxH): 238 x 488 x 387 mm"