Tripp Lite logo

Tripp Lite SmartOnline Expandable UPS System uninterruptible power supply (UPS) 2,2 kVA 1600 W

Article code:
Icecat Product ID:
Data-sheet quality:
created/standardized by Icecat
Product views:
55957
Info modified on:
21 Oct 2022, 10:32:10
Guarantee:
2 year
Long product name Tripp Lite SmartOnline Expandable UPS System uninterruptible power supply (UPS) 2,2 kVA 1600 W:

SmartOnline Expandable UPS System - 2200 VA - Black

Tripp Lite SmartOnline Expandable UPS System uninterruptible power supply (UPS) 2,2 kVA 1600 W:

2200VA on-line, double-conversion UPS system for critical server, network and telecommunications equipment. 2U rackmount form factor with an installed depth of only 19 inches. Expandable battery runtime with optional BP48V24-2U (limit 1) and BP48V60RT-3U (multi-pack compatible) external battery packs. Full-time sine wave 110 or 120V output with +/-2% voltage regulation. Online, double-conversion Uninterruptible Power Supply (UPS) actively converts raw incoming AC power to DC, then re-converts output back to completely regulated, filtered AC output. Operates continuously without using battery power during brownouts to 65V and overvoltages to 150V. Highly efficient operation in optional economy mode saves BTU heat output and energy costs. NEMA 5-20P input plug. NEMA 5-15/20R and NEMA L5-20R output receptacles. Network-grade AC surge and noise suppression. Zero transfer time between AC and battery operation. Network-grade AC surge and noise suppression. Zero transfer time between AC and battery operation. Network management interfaces support simultaneous communications via USB port, DB9 serial port and SNMPWEBCARD slot. Built-in DB9 port offers both enhanced RS-232 enabled monitoring data, plus contact closure monitoring ability. HID-compliant USB interface enables integration with built-in power management and auto shutdown features of Windows and Mac OS X. Supports simultaneous detailed monitoring of equipment load levels, self-test data and utility power conditions via all 3 network interfaces. Includes PowerAlert monitoring software and complete cabling. Emergency Power Off (EPO) interface. Integrated two-bank PDU switching supports load shedding and remote reboot of connected equipment. 3-stage metered current monitoring and battery charge status LEDs. LED display panel easily rotates for viewing in rackmount or tower configurations. Dataline surge suppression for dialup, DSL or network Ethernet connection. Utility power and voltage regulation LEDs. Audible alarm. Self-test. Fault-tolerant auto-bypass mode. 4-post rackmount accessories included; 2-9USTAND tower kit and 2POSTRMKITWM 2-post rack & wallmount accessories available. Field-replaceable, hot-swappable internal batteries and external battery packs. Attractive all-black color scheme.

- SmartOnline high performance UPS system is ideal for critical voice, data, medical and industrial network applications.
- True on-line, double-conversion UPS provides perfectly regulated sine wave output within 2% of 110/120V (user selectable) under all usage conditions.
- Maintains continuous operation through blackouts, voltage fluctuations and surges with zero transfer time.
- Highly efficient operation in optional economy mode setting, saving BTU heat output and energy costs.
- Removes harmonic distortion, fast electrical impulses, frequency variations and other hard to solve power problems not addressed by other UPS types.
- Corrects line voltage conditions as low as 65V and as high as 150V back to selectable 110/120V (+/-2%) values.
- Standard internal battery set offers 14 min. runtime at half load (800W) and 4.5 min. at full load (1600W).
- Automatic restart after power outages that drain batteries and shutdown UPS immediately provide AC power to equipment when power returns.
- Extended runtime available with optional BP48V24-2U (limit 2 w/48VDCSPLITTER) or BP48V60RT3U (no limit) external battery packs.
- Compact rackmount form factor installs using only 2 rack spaces (2U) with a maximum installed depth of only 19 inches.
- Ships with all mounting accessories for 4 post rackmount installation.
- Optional 2POSTRMKITWM enables 2 post rackmount or wallmount installation.
- Optional 2-9USTAND accessory enables small-footprint upright tower placement.
- Fault tolerant auto-bypass maintains continuous utility output to connected equipment, even in cases where the UPS suffers internal failure and requires maintenance.
- Network interfaces support simultaneous communications via built-in USB, DB9 serial / contact-closure and SNMPWEBCARD slot.
- HID compliant USB interface enables integration with built-in power management and auto shutdown features of Windows and Mac OS X.
- Included PowerAlert UPS monitoring software supports safe unattended shutdown, monitoring and control via local connected servers, plus any number of additional servers over IP.
- UPS interface supports on-battery, low-battery, power-restored, AC-voltage, DC-voltage, output current monitoring, battery charge current, battery capacity, AC line frequency, timed inverter sutoff, activate self-test, load bank output power control and remote reboot, UPS nominal voltage adjustment and UPS line to battery power voltage setpoints.
- Built-in Emergency Power Off (EPO) interface with cable.
- NEMA 5-20P input plug; NEMA 5-15/20R & NEMA L5-20R output receptacles.
- Integrated 2 bank switched PDU enables remote outlet management for load shedding or remote reboot of individual load banks (each bank has 3 outlets).
- Front panel LEDs offer current monitoring and battery charge level information.
- UPS ships fully assembled in full compliance with DOT regulations, no time consuming connection of internal batteries by user required.
- Single line TEL/DSL or network ethernet line surge suppression.

Short summary description Tripp Lite SmartOnline Expandable UPS System uninterruptible power supply (UPS) 2,2 kVA 1600 W:

Tripp Lite SmartOnline Expandable UPS System, 2,2 kVA, 1600 W, 570 J, 4 ms, 4,5 min, 14 min

Long summary description Tripp Lite SmartOnline Expandable UPS System uninterruptible power supply (UPS) 2,2 kVA 1600 W:

Tripp Lite SmartOnline Expandable UPS System. Output power capacity: 2,2 kVA, Output power: 1600 W, Surge energy rating: 570 J. Typical backup time at full load: 4,5 min, Typical backup time at half load: 14 min, Battery recharge time: 6 h. Form factor: Rackmount, Product color: Black, Cable length: 3 m. Weight: 21,5 kg, Package weight: 26 kg. Output connections: 6 x 5-15/20R 1 x L5-20R, Input connection type: 5-20P, Dimensions (WxDxH): 444 x 483 x 89 mm

Specs
Recommended products
Loading...
We use cookies to ensure that we give you the best experience on our website. If you continue to use this site we will assume that you are happy with it.